- Abstract:
-
The design, modelling and testing of a film cooling system intended for the casing of an unshrouded HP turbine rotor is described in this thesis. Due to the dense network of small film cooling holes employed in such a system, this is often referred to as a casing effusion cooling scheme. Though there are patent references to such systems, there is as yet very limited published material on the aero thermal performance of such film cooling schemes. The casing of an unshrouded HP rot...
Expand abstract
Actions
Funding
+ Engineering & Physical Sciences Research Council