Journal article icon

Journal article : Review

Assessing a Stimulator Modification for Simultaneous Noninvasive Auricular Vagus Nerve Stimulation and MRI

Abstract:
Background and Purpose: The vagus nerve can be stimulated noninvasively at the ear using transcutaneous auricular vagus nerve stimulation (taVNS). Concurrent functional MRI (fMRI) permits study of taVNS‐induced changes in brain dynamics, a key requisite for precision neurostimulation. However, there is no standardized protocol for how to safely apply taVNS during MRI. One major risk is temperature increase exceeding innocuous thresholds due to coupling of the emitted radio frequency (RF) pulse during imaging. Thus, we developed and tested a stimulator cable configuration with floating ground cable traps and filter plate connectors. Methods: We measured temperature, resonance of the stimulation electrodes, and current interference using unmodified and modified stimulation cables. Measurements were conducted across three sites using different 3T MRI scanner models, stimulators, and stimulation strengths with phantoms and human participants. Results: The modified compared to the unmodified cable considerably reduced RF heating as the relative temperature increase stayed well below the 2 K threshold specified by the ASTM F2182 standard. Additionally, in accordance with ASTM 2119, we can rule out potential distortion and signal loss around the electrodes due to current flow from the stimulator and demonstrate that impaired image quality in brainstem and midbrain regions is recovered using the modified cable. Conclusions: We show that adding floating ground cable traps to the stimulator cable allows the safe use of taVNS with fMRI and may improve image quality in functional imaging. To enable other researchers to modify their hardware in the same way, we provide details of the modifications.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1111/jon.70098

Authors

More by this author
Role:
Author
ORCID:
0000-0002-9974-4557


More from this funder
Funder identifier:
https://ror.org/018mejw64
More from this funder
Funder identifier:
https://ror.org/0375f4d26
More from this funder
Funder identifier:
https://ror.org/01cwqze88
More from this funder
Funder identifier:
https://ror.org/02ymzm013


Publisher:
Wiley
Journal:
Journal of Neuroimaging More from this journal
Volume:
35
Issue:
6
Article number:
e70098
Publication date:
2025-11-06
Acceptance date:
2025-10-13
DOI:
EISSN:
1552-6569
ISSN:
1051-2284


Language:
English
Keywords:
Subtype:
Review
Pubs id:
2329030
UUID:
uuid_69a65bf6-f238-4d0c-a952-0a078c1cfe71
Local pid:
pubs:2329030
Source identifiers:
3449181
Deposit date:
2025-11-07
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP