Coriolis Mass Flow Metering for Wet Gas

Abstract:
Most two-phase applications for Coriolis mass flow metering are for low Gas Void Fraction (GVF) conditions, i.e. where the process fluid is essentially liquid with relatively low levels of entrained air or gas. There are particular challenges associated with metering wet gas, where the GVF exceeds 95%. Established wet gas metering techniques are typically based on a differential pressure-type device (for example an orifice plate or V-cone). It is well-known that such devices over-read compared to a dry gas calibration; equations to correct the reading are available if the degree of gas "wetness" is known. For Coriolis mass flow metering of wet gas, two approaches are described. The natural extension of the low GVF techniques is to map the observed mass flow and density readings onto estimates of the flow rates of the gas and liquid components. The alternative is to use the Coriolis meter to estimate the degree of gas "wetness" (e.g. the Lockhart-Martinelli number) and to apply a conventional correlation (e.g. Murdock or Chisholm) to a differential pressure flow reading. A prototype Coriolis-based wet gas meter is described, together with results from laboratory trials at CEESI in Colorado, and from extended field trials at BP's Wamsutter gas field in Wyoming.
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1177/002029400804100703

Authors



Journal:
MEASUREMENT and CONTROL More from this journal
Volume:
41
Issue:
7
Pages:
213-216
Publication date:
2008-09-01
DOI:
ISSN:
0020-2940


Language:
English
Pubs id:
pubs:292648
UUID:
uuid:f896bdad-003f-4eae-98d8-b530e9a1bf16
Local pid:
pubs:292648
Source identifiers:
292648
Deposit date:
2013-11-16

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP