Journal article icon

Journal article

Theoretical analysis of the two-electron transfer reaction and experimental studies with surface-confined cytochrome c peroxidase using large-amplitude Fourier transformed AC voltammetry.

Abstract:
A detailed analysis of the cooperative two-electron transfer of surface-confined cytochrome c peroxidase (CcP) in contact with pH 6.0 phosphate buffer solution has been undertaken. This investigation is prompted by the prospect of achieving a richer understanding of this biologically important system via the employment of kinetically sensitive, but background devoid, higher harmonic components available in the large-amplitude Fourier transform ac voltammetric method. Data obtained from the conventional dc cyclic voltammetric method are also provided for comparison. Theoretical considerations based on both ac and dc approaches are presented for cases where reversible or quasi-reversible cooperative two-electron transfer involves variation in the separation of their reversible potentials, including potential inversion (as described previously for solution phase studies), and reversibility of the electrode processes. Comparison is also made with respect to the case of a simultaneous two-electron transfer process that is unlikely to occur in the physiological situation. Theoretical analysis confirms that the ac higher harmonic components provide greater sensitivity to the various mechanistic nuances that can arise in two-electron surface-confined processes. Experimentally, the ac perturbation with amplitude and frequency of 200 mV and 3.88 Hz, respectively, was employed to detect the electron transfer when CcP is confined to the surface of a graphite electrode. Simulations based on cooperative two-electron transfer with the employment of reversible potentials of 0.745 ± 0.010 V, heterogeneous electron transfer rate constants of between 3 and 10 s(-1) and charge transfer coefficients of 0.5 for both processes fitted experimental data for the fifth to eighth ac harmonics. Imperfections in theory-experiment comparison are consistent with kinetic and thermodynamic dispersion and other nonidealities not included in the theory used to model the voltammetry of surface-confined CcP.
Publication status:
Published

Actions

Access Document

Publisher copy:
10.1021/la205037e

Authors


Journal:
Langmuir : the ACS journal of surfaces and colloids More from this journal
Volume:
28
Issue:
25
Pages:
9864-9877
Publication date:
2012-06-01
DOI:
EISSN:
1520-5827
ISSN:
0743-7463


Language:
English
Keywords:
Pubs id:
pubs:332812
UUID:
uuid:f86c0110-3e6c-49fa-b648-993b68f4dd10
Local pid:
pubs:332812
Source identifiers:
332812
Deposit date:
2012-12-19
ARK identifier:

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP