Abstract:

Background

Remote self-administered visual acuity (VA) tests have the potential to allow patients and non-specialists to assess vision without eye health professional input. Validation in pragmatic trials is necessary to demonstrate the accuracy and reliability of tests in relevant settings to justify deployment. Here, published pragmatic trials of these tests were synthesised to summarise the effectiveness of available options and appraise the quality of their supporting evidence.

Methods

A systematic review was undertaken in accordance with a preregistered protocol (CRD42022385045). The Cochrane Library, Embase, MEDLINE, and Scopus were searched. Screening was conducted according to the following criteria: (1) English language; (2) primary research article; (3) visual acuity test conducted out of eye clinic; (4) no clinical administration of remote test; (5) accuracy or reliability of remote test analysed. There were no restrictions on trial participants. Quality assessment was conducted with QUADAS-2.

Results

Of 1227 identified reports, 10 studies were ultimately included. One study was at high risk of bias and two studies exhibited concerning features of bias; all studies were applicable. Three trials-of DigiVis, iSight Professional, and Peek Acuity-from two studies suggested that accuracy of the remote tests is comparable to clinical assessment. All other trials exhibited inferior accuracy, including conflicting results from a pooled study of iSight Professional and Peek Acuity. Two studies evaluated test-retest agreement-one trial provided evidence that DigiVis is as reliable as clinical assessment. The three most accurate tests required access to digital devices. Reporting was inconsistent and often incomplete, particularly with regards to describing methods and conducting statistical analysis.

Conclusions

Remote self-administered VA tests appear promising, but further pragmatic trials are indicated to justify deployment in carefully defined contexts to facilitate patient or non-specialist led assessment. Deployment could augment teleophthalmology, non-specialist eye assessment, pre-consultation triage, and autonomous long-term monitoring of vision.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1371/journal.pone.0281847

Authors

More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0001-8968-4768
More by this author
Role:
Author
ORCID:
0009-0003-0678-8935
More by this author
Role:
Author
ORCID:
0000-0002-8464-5708


Publisher:
Public Library of Science
Journal:
PLoS ONE More from this journal
Volume:
18
Issue:
6
Pages:
e0281847-e0281847
Publication date:
2023-06-22
DOI:
EISSN:
1932-6203
ISSN:
1932-6203


Language:
English
Keywords:
Pubs id:
2341960
Local pid:
pubs:2341960
Source identifiers:
W4381716591
Deposit date:
2025-12-03
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP