IntroductionShoulder arthroplasty procedures have increased significantly, with reverse shoulder arthroplasty (RSA) becoming more common. While RSA revision rates are reported as low, these figures may not accurately reflect implant success. Factors such as older patient demographics and surgeon reluctance to perform complex revisions may contribute to lower revision rates. This perception may encourage broader RSA use in younger patients, potentially increasing long-term revision burdens. This study examines whether revision thresholds differ between shoulder arthroplasty types to determine if low revision rates reported signify true implant success.MethodsAll shoulder arthroplasties from the 1st April 2012 to the 31st March 2022 were requested from the National Joint Registry (NJR). Mean postoperative Oxford Shoulder Score (OSS) was calculated for RSA, total shoulder arthroplasty (TSA), and hemiarthroplasty (HA). Revision rates were analysed between implants for patients with a mean postoperative OSS of ResultsAmong 21,918 NJR patients with postoperative OSS data, HA had the highest proportion of patients with 'unsatisfactory' function (38.12%), followed by RSA (26.99%) and TSA (15.35%). 4.87% of RSA patients with unsatisfactory function were revised, significantly less than TSA (10.58%) and HA (13.86%) (p ConclusionRSA has lower revision rates than HA and TSA; however, this may not reflect superior implant performance. Patients with poor RSA function are less likely to undergo revision, suggesting higher revision thresholds. As RSA use expands, its assumed low revision rate must be reassessed to prevent long-term burdens of poorly functioning implants. Further research is needed to determine whether surgical selection bias influences revision rates and to establish additional benchmarks or surrogates in joint registries for a more comprehensive assessment of implant performance
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1371/journal.pone.0330975

Authors

More by this author
Role:
Author
ORCID:
0000-0002-9674-1553
More by this author
Role:
Author
ORCID:
0000-0002-4728-5109
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0002-5452-8578
More by this author
Role:
Author
ORCID:
0000-0002-2732-756X
More by this author
Role:
Author
ORCID:
0000-0002-6892-351X


Publisher:
Public Library of Science
Journal:
PLoS ONE More from this journal
Volume:
20
Issue:
8
Pages:
e0330975-e0330975
Publication date:
2025-08-26
DOI:
EISSN:
1932-6203
ISSN:
1932-6203


Language:
English
Keywords:
Pubs id:
2286003
Local pid:
pubs:2286003
Source identifiers:
W4413751144
Deposit date:
2026-05-25
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP