Journal article
Self-calibration for a 3D laser
- Abstract:
- In this paper we describe a method for the automatic self-calibration of a 3D laser sensor. We wish to acquire crisp point clouds and so we adopt a measure of crispness to capture point cloud quality. We then pose the calibration problem as the task of maximizing point cloud quality. Concretely, we use Rényi Quadratic Entropy to measure the degree of organization of a point cloud. By expressing this quantity as a function of key unknown system parameters, we are able to deduce a full calibration of the sensor via an online optimization. Beyond details on the sensor design itself, we fully describe the end-to-end intrinsic parameter calibration process and the estimation of the clock skews between the constituent microprocessors. We analyse performance using real and simulated data and demonstrate robust performance over 30 test sites. © The Author(s) 2011.
- Publication status:
- Published
Actions
Authors
- Journal:
- INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH More from this journal
- Volume:
- 31
- Issue:
- 5
- Pages:
- 675-687
- Publication date:
- 2012-04-01
- DOI:
- EISSN:
-
1741-3176
- ISSN:
-
0278-3649
- Language:
-
English
- Keywords:
- Pubs id:
-
pubs:329440
- UUID:
-
uuid:ee597eb3-b687-490f-be52-204e50447eb6
- Local pid:
-
pubs:329440
- Source identifiers:
-
329440
- Deposit date:
-
2013-11-16
Terms of use
- Copyright date:
- 2012
If you are the owner of this record, you can report an update to it here: Report update to this record