Journal article
Apparent diffusion coefficient as a quantitative biomarker for prostate cancer treatment response on a 1.5 Tesla magnetic resonance-linear accelerator: Impact of image registration and acquisition type
- Abstract:
- Background and purposeDiffusion-weighted magnetic resonance imaging (DW-MRI) is a quantitative biomarker for cancer detection and treatment monitoring. On magnetic resonance-linear accelerator (MR-Linac) systems, diffusion-weighted echo planar imaging (DW-EPI) suffers from geometric distortion, reducing the repeatability of apparent diffusion coefficient (ADC) measurements. This study evaluated the effect of low-distortion split acquisition of fast spin-echo signal (SPLICE) sequences, and of image registration on the repeatability coefficient (RC) of ADC.Materials and methodsADC bias, repeatability, signal-to-noise ratio (SNR) and geometric fidelity were measured in a diffusion phantom using three DW-EPI and two DW-SPLICE protocols. ADC short-term and long-term RCs were measured in healthy volunteers. In patients, the registration of DW-EPI to unweighted images (b0) was tested for its effect on RC in gross tumour volume (GTV) and non-tumour prostate (NT-P), and for its ability to detect significant ADC changes.ResultsPhantom experiments showed strong linear correlation with ground-truth ADC (R2 > 0.99). Among EPI protocols, DW-EPI-AP offered the best balance of high SNR and low RC, while Z-direction encoded DW-EPI was the most variable. Both DW-SPLICE variants exhibited reduced distortion compared with EPI but poorer repeatability. In volunteers, long-term RCs (8.0-33.7 %) varied more than short-term RCs (8.9-15.4 %). In patients, registration improved RCs (GTV: 28.0 → 25.1 %; NT-P: 19.6 → 12.6 %) and improved detection of significant ADC change in patients (GTV: 0/6 → 1/6; NT-P: 2/6 → 5/6).ConclusionRC and accuracy of DW-EPI agrees with published literature and improves after registration. DW-SPLICE shows lower geometric distortion but would require further optimization and validation to improve repeatability.
- Publication status:
- Published
- Peer review status:
- Peer reviewed
Actions
Access Document
- Files:
-
-
(Preview, Version of record, pdf, 5.2MB, Terms of use)
-
- Publisher copy:
- 10.1016/j.phro.2025.100851
Authors
- Publisher:
- Elsevier BV
- Journal:
- Physics and imaging in radiation oncology More from this journal
- Volume:
- 36
- Pages:
- 100851
- Publication date:
- 2025-10-13
- Acceptance date:
- 2025-10-08
- DOI:
- EISSN:
-
2405-6316
- ISSN:
-
2405-6316
- Pmid:
-
41146990
- Language:
-
English
- Keywords:
- UUID:
-
uuid_ea24ff5e-da32-4f09-a987-56e4e4c4714d
- Source identifiers:
-
3438499
- Deposit date:
-
2025-11-05
- ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.
Terms of use
- Copyright date:
- 2025
- Licence:
- CC Attribution (CC BY)
If you are the owner of this record, you can report an update to it here: Report update to this record