Apparent diffusion coefficient as a quantitative biomarker for prostate cancer treatment response on a 1.5 Tesla magnetic resonance-linear accelerator: Impact of image registration and acquisition type

Abstract:
Background and purposeDiffusion-weighted magnetic resonance imaging (DW-MRI) is a quantitative biomarker for cancer detection and treatment monitoring. On magnetic resonance-linear accelerator (MR-Linac) systems, diffusion-weighted echo planar imaging (DW-EPI) suffers from geometric distortion, reducing the repeatability of apparent diffusion coefficient (ADC) measurements. This study evaluated the effect of low-distortion split acquisition of fast spin-echo signal (SPLICE) sequences, and of image registration on the repeatability coefficient (RC) of ADC.Materials and methodsADC bias, repeatability, signal-to-noise ratio (SNR) and geometric fidelity were measured in a diffusion phantom using three DW-EPI and two DW-SPLICE protocols. ADC short-term and long-term RCs were measured in healthy volunteers. In patients, the registration of DW-EPI to unweighted images (b0) was tested for its effect on RC in gross tumour volume (GTV) and non-tumour prostate (NT-P), and for its ability to detect significant ADC changes.ResultsPhantom experiments showed strong linear correlation with ground-truth ADC (R2 > 0.99). Among EPI protocols, DW-EPI-AP offered the best balance of high SNR and low RC, while Z-direction encoded DW-EPI was the most variable. Both DW-SPLICE variants exhibited reduced distortion compared with EPI but poorer repeatability. In volunteers, long-term RCs (8.0-33.7 %) varied more than short-term RCs (8.9-15.4 %). In patients, registration improved RCs (GTV: 28.0 → 25.1 %; NT-P: 19.6 → 12.6 %) and improved detection of significant ADC change in patients (GTV: 0/6 → 1/6; NT-P: 2/6 → 5/6).ConclusionRC and accuracy of DW-EPI agrees with published literature and improves after registration. DW-SPLICE shows lower geometric distortion but would require further optimization and validation to improve repeatability.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1016/j.phro.2025.100851

Authors

More by this author
Institution:
University of Oxford
Oxford college:
St John's College
Role:
Author


Publisher:
Elsevier BV
Journal:
Physics and imaging in radiation oncology More from this journal
Volume:
36
Pages:
100851
Publication date:
2025-10-13
Acceptance date:
2025-10-08
DOI:
EISSN:
2405-6316
ISSN:
2405-6316
Pmid:
41146990


Language:
English
Keywords:
UUID:
uuid_ea24ff5e-da32-4f09-a987-56e4e4c4714d
Source identifiers:
3438499
Deposit date:
2025-11-05
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP