Journal article icon

Journal article

Comparing EUS-guided lumen-apposing metal stents with and without integrated electrocautery for endoscopic drainage of walled-off pancreatic necrosis

Abstract:
Background and objectivesEUS-guided drainage using lumen-apposing metal stents (LAMSs) has become standard treatment of symptomatic walled-off pancreatic necrosis (WOPN). Delivery systems with integrated electrocautery (EC) enable direct access and stent deployment, whereas the conventional stent insertion requires several steps including access using a needle or cystotome, wire insertion, and enlargement of the created tract before the stent placement. This study aimed to compare the practicality of EUS-guided procedures and their outcomes between conventional LAMSs (cLAMSs) and integrated EC (EC-LAMSs).MethodsIn consecutive patients undergoing EUS-guided LAMS insertion with or without integrated EC, data on procedure time, sedation, and technical and clinical success, as well as adverse events, were analyzed.ResultsFrom our prospectively maintained database, we analyzed 107 consecutive procedures of transmural EUS-stenting for drainage of WOPN. Thirty-nine cLAMSs and 68 EC-LAMSs were placed. Mean WOPN size was 12.9 ± 4.2 cm with mean 30% ± 15% solid necrosis.Procedure times were shorter with EC-LAMSs (18.0 ± 6.6 vs. 39.7 ± 8.3 minutes; P < 0.05). All EUS-guided procedures with cLAMS drainage were performed under propofol sedation administered by anesthetist. In the EC-LAMS group, 36 patients tolerated the procedure under intravenous sedation (fentanyl/midazolam), and 17 interventions were performed as day case procedures. Adverse events and clinical outcome did not differ between both groups.ConclusionCompared with cLAMS, EC-LAMS deployment is faster and technically less demanding. This allows performing the procedure under conventional intravenous sedation and as day case procedure in selected patients.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1097/eus.0000000000000131

Authors

More by this author
Institution:
University of Oxford
Role:
Author
More by this author
Institution:
University of Oxford
Role:
Author
More by this author
Role:
Author
ORCID:
0000-0001-6015-6347
More by this author
Institution:
University of Oxford
Role:
Author


Publisher:
Lippincott, Williams & Wilkins
Journal:
Endoscopic Ultrasound More from this journal
Volume:
14
Issue:
3
Pages:
137-141
Publication date:
2025-05-01
DOI:
EISSN:
2226-7190
ISSN:
2303-9027
Pmid:
41584024


Language:
English
Keywords:
Pubs id:
2412304
UUID:
uuid_cf53f826-9960-4514-bff1-0a682f40f248
Local pid:
pubs:2412304
Source identifiers:
3720292
Deposit date:
2026-02-03
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP