Abstract:
Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium‐labeled (2H) glucose as non‐invasive tracer. Reliable concentration estimation of 2H‐Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue‐specific T1 and T2 relaxation times (e.g., in gray and white matter) have not been determined. Such measurements are time‐consuming and particularly challenging in the presence of dynamically changing metabolite levels (e.g. 2H Glc and 2H Glx). This study aimed to assess T1 and T2 relaxation times of deuterated resonances, i.e., water, Glc and Glx in human gray and white matter using inversion recovery and Hahn spin‐echo 2H MRSI (magnetic resonance spectroscopic imaging), respectively, with non‐Cartesian concentric ring trajectory readout (CRT) including specific k‐space reordering at 7 T. The sequence was validated using phantom measurements and all results were compared to unlocalized acquisitions. Thirteen healthy volunteers participated in the study, with 10 of them scanned ~90 min after oral administration of 0.8 g/kg [6,6′‐2H]‐glucose. Significantly different T1 and T2 relaxation was observed between GM and WM for 2H water (T1GM/WM/unlocalized = 358 ± 21/328 ± 12/335 m ± 6 ms, p = 0.01) and 2H Glx (T2GM/WM/unlocalized = 37 ± 2/35 ± 2/33 ± 3 ms, p = 0.02), respectively, consistent with unlocalized acquisitions. No significant regional differences were found for 2H water (T2GM/WM/unlocalized = 36 ± 2/34 ± 2/31 ± 2 ms, p = 0.08), 2H Glc (T1GM/WM/unlocalized = 70 ± 5/73 ± 4/80 ± 5 ms, p = 0.13; T2GM/WM/unlocalized = 36 ± 1/34 ± 2/34 ± 2 ms, p = 0.24) and Glx (T1GM/WM/unlocalized = 172 ± 15/172 ± 12/165 ± 11 ms, p = 1.00). Knowledge of tissue‐specific relaxation times can enhance the accuracy of concentration estimation and metabolic flux rates in future studies, potentially improving our understanding of various brain diseases such as cancer, neurodegenerative diseases or diabetes, which are often linked to impaired glucose metabolism.
Publication status:
Published
Peer review status:
Peer reviewed

Actions


Access Document


Files:
Publisher copy:
10.1002/nbm.5311

Authors


More by this author
Role:
Author
ORCID:
0009-0004-2393-9579
More by this author
Role:
Author
ORCID:
0000-0002-0130-3463
More by this author
Role:
Author
ORCID:
0000-0003-1808-8349


More from this funder
Funder identifier:
https://ror.org/01cwqze88


Publisher:
Wiley
Journal:
NMR in Biomedicine More from this journal
Volume:
38
Issue:
2
Article number:
e5311
Publication date:
2024-12-19
Acceptance date:
2024-12-05
DOI:
EISSN:
1099-1492
ISSN:
0952-3480


Language:
English
Keywords:
Source identifiers:
2514511
Deposit date:
2024-12-20
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP