Journal article icon

Journal article

Do patients actually do what we ask: patient fidelity and persistence to the targets and self-management for the control of blood pressure in stroke and at risk groups blood pressure self-management intervention

Abstract:
Objective: Self-management of hypertension can reduce and control blood pressure (BP) compared with clinic monitoring. However, self-management relies on patients following an algorithm, which may be variably adhered to. This study reports fidelity of high-risk patients to the self-management algorithm set by the TASMIN-SR trial. Methods: Patients with hypertension, above target clinic BP and one or more of stroke, diabetes, coronary heart disease or chronic kidney disease, were invited to self-monitor following an individualized self-titration algorithm. Home BP readings and medication change details were submitted monthly for 12 months. Readings downloaded from patients’ electronic monitors were compared with written submissions, and protocol fidelity was assessed. Results: Two hundred and seventy-six patients were randomized to self-management and 225 (82%) completed the required training sessions. Of these, 166 (74%) completed self-management. A total of 11385 (89.6%) submitted readings were accurate compared with corresponding downloaded monitor readings. Mean error rate was 5.2% per patient, which increased with age but not comorbidities. Patients made 475 of 683 (69.5%) algorithm-recommended medication changes, equating to nearly three medication changes per patient. Mean SBP for patients who completed training and made all recommended changes dropped from 141 mmHg (95% CI 138.26–144.46) to 121 mmHg (95% CI 118.30–124.17 mmHg) compared with 129 mmHg (95% CI 125.27–136.73 mmHg) for patients who made none. Conclusion: Most patients randomized to self-management completed training; however, 36% of these had dropped out by 12 months. Self-monitoring was largely undertaken properly and accurately recorded. Fidelity with self-management was associated with lower achieved SBP. Successful implementation of self-management into daily practice requires careful training and should be accompanied by monitoring of fidelity.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1097/hjh.0000000000001738

Authors

More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Primary Care Health Sciences
Role:
Author


NIHR National School of Primary Care Research More from this funder
Grant:
NSPCR 16
National Institute for Health Research More from this funder
Grant:
RP-PG 0606–1153
National Institute for Health Research (NIHR) Collaboration for Leadership in Applied Health Research and Care More from this funder
Funding agency for:
Schwartz, C


Publisher:
Wolters Kluwer Health
Journal:
Journal of Hypertension More from this journal
Volume:
36
Issue:
8
Pages:
1753–1761
Publication date:
2018-06-07
Acceptance date:
2018-03-01
DOI:
EISSN:
1473-5598
ISSN:
0263-6352
Pmid:
29889157


Language:
English
Keywords:
Pubs id:
pubs:857693
UUID:
uuid:bd3aeb82-2757-492f-a5ee-3f381d574ed4
Local pid:
pubs:857693
Source identifiers:
857693
Deposit date:
2018-06-22
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP