Journal article icon

Journal article

Validation protocols for blood pressure measuring devices: the impact of the European Society of Hypertension International Protocol and the development of a Universal Standard

Abstract:
In the last three decades protocols for the validation of blood pressure measuring devices have been developed by the US Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League, the European Society of Hypertension Working Group on blood pressure Monitoring and the International Organization for Standardization. The European Society of Hypertension International Protocol required much smaller sample size than the other protocols, aiming to reduce the time, resources and cost of validation studies and thereby increase the number of validated devices. Given its specifications, the European Society of Hypertension International Protocol was adequate for ‘high- and low-accuracy’ devices, yet assessment of ‘moderate accuracy’ devices had high uncertainty with resultant high rate of device failure. Thus, devices validated using the European Society of Hypertension International Protocol should be considered to be as accurate as those validated with the previous Association for the Advancement of Medical Instrumentation or British Hypertension Society protocols. However, the European Society of Hypertension International Protocol did not allow subgroup evaluation (arm sizes, special populations, etc). The mission of the European Society of Hypertension International Protocol to promote the concept of validation has been well achieved, as almost double studies have been published using it than all the other protocols together. However, the maintenance of different validation protocols is confusing and therefore experts from the Association for the Advancement of Medical Instrumentation, European Society of Hypertension International Protocol and International Organization for Standardization have now developed the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) as the recommended 21st-century procedure for worldwide application. The European Society of Hypertension Working Group has published a practical guide for using the Universal Standard. It is in the interests of all scientific bodies to propagate the Universal Standard and ensure its wide implementation.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1097/mbp.0000000000000391

Authors


Publisher:
Wolters Kluwer Health
Journal:
Blood Pressure Monitoring More from this journal
Volume:
24
Issue:
4
Pages:
163-166
Publication date:
2019-05-01
Acceptance date:
2019-04-16
DOI:
EISSN:
1473-5725
ISSN:
1359-5237


Language:
English
Keywords:
Pubs id:
pubs:1003447
UUID:
uuid:af39134b-546b-4018-9125-794f66edf07a
Local pid:
pubs:1003447
Source identifiers:
1003447
Deposit date:
2019-05-29
ARK identifier:

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP