Automated versus non-automated weaning for reducing the duration of mechanical ventilation for critically ill adults and children: a cochrane systematic review and meta-analysis

Abstract:
Abstract Introduction Automated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events. Methods Electronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling. Results We identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I 2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high. Conclusions Automated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1186/s13054-015-0755-6

Authors

More by this author
Role:
Author
ORCID:
0000-0003-1700-3972
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0003-3969-7792
More by this author
Role:
Author
ORCID:
0000-0002-2689-4335
More by this author
Role:
Author
ORCID:
0000-0001-5684-3398
More by this author
Role:
Author
ORCID:
0000-0002-3283-1947


Publisher:
BioMed Central
Journal:
Critical Care More from this journal
Volume:
19
Issue:
1
Pages:
48-48
Publication date:
2015-02-04
DOI:
EISSN:
1466-609X
ISSN:
1364-8535


Language:
English
Keywords:
Pubs id:
1235143
Local pid:
pubs:1235143
Source identifiers:
W2088085411
Deposit date:
2025-12-06
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP