Journal article icon

Journal article

Faster and More Robust CK Reaction Rate Estimation at 3T Using Acquisition‐Weighted 31 P Cardiac 1D ‐ MRSI With Compartment‐Based Reconstruction

Abstract:
Purpose: Quantification of the creatine kinase (CK) forward reaction rate (kf) in the human heart using phosphorus magnetic resonance spectroscopy is clinically important; however, it is limited by long acquisition times, operator subjectivity in analysis, and potential skeletal muscle contamination. This study evaluates if combining compartment‐based reconstruction techniques with acquisition‐weighted (AW) Triple Repetition Time Saturation Transfer (TRiST) acquisitions could overcome these challenges. Methods: Healthy volunteers were scanned with a fully weighted (FW) TRiST protocol twice, and once with an AW TRiST protocol on a 3T MRI. The resulting spectra were reconstructed with conventional Fourier Transform (FT), as well as compartment‐based reconstruction techniques: Spectroscopy with Linear Algebra Modeling (SLAM), Spectral Localization by IMaging (SLIM), and an unweighted mean of the FT spectra (ROI‐FT). kf values were calculated and compared across reconstruction methods and acquisition types. Results: The cardiac kf values from FW TRiST were 0.21 ± 0.07 s−1 (FT), 0.26 ± 0.08 s−1 (SLAM), 0.26 ± 0.07 s−1 (SLIM), and 0.30 ± 0.10s−1 (ROI‐FT). Corresponding values from AW TRiST were 0.27 ± 0.07 s−1, 0.25 ± 0.05 s−1, 0.25 ± 0.04 s−1, and 0.24 ± 0.08 s−1, respectively. No significant differences were observed between FW and AW results. A significant decrease in cardiac PCr/ATP ratios was observed for SLAM and SLIM reconstructed data, suggesting decreased signal contamination from skeletal muscle. Conclusion: Compartment‐based reconstruction techniques minimize the operator subjectivity present in the current FT method of analyzing TRiST experiments, in addition to reducing skeletal muscle contamination. When combined with an AW acquisition, scan times were reduced by 47% without compromising kf accuracy. This method provides a more robust and efficient evaluation of in vivo cardiac metabolism.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1002/mrm.70408

Authors

More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0009-0007-5954-8977
More by this author
Institution:
University of Oxford
Role:
Author
More by this author
Institution:
University of Oxford
Role:
Author
More by this author
Institution:
University of Oxford
Role:
Author
More by this author
Institution:
University of Oxford
Role:
Author


More from this funder
Funder identifier:
10.13039/501100005357
Grant:
21‐0299
More from this funder
Funder identifier:
https://ror.org/02wdwnk04
More from this funder
Funder identifier:
https://ror.org/029chgv08
More from this funder
Funder identifier:
https://ror.org/037nx0e70


Publisher:
Wiley
Journal:
Magnetic Resonance in Medicine More from this journal
Article number:
mrm.70408
Publication date:
2026-04-26
Acceptance date:
2026-04-16
DOI:
EISSN:
1522-2594
ISSN:
0740-3194


Language:
English
Pubs id:
2412396
Local pid:
pubs:2412396
Source identifiers:
3988662
Deposit date:
2026-04-27
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP