Journal article icon

Journal article

An experimental comparison of the Marcus-Hush and Butler-Volmer descriptions of electrode kinetics applied to cyclic voltammetry. The one electron reductions of europium (III) and 2-methyl-2-nitropropane studied at a mercury microhemisphere electrode

Abstract:
We present a comparative experimental evaluation of the Butler-Volmer and Marcus-Hush models using cyclic voltammetry at a microelectrode. Numerical simulations are used to fit experimental voltammetry of the one electron reductions of europium (III) and 2-methyl-2-nitropropane, in water and acetonitrile, respectively, at a mercury microhemisphere electrode. For Eu (III) very accurate fits to experiment were obtained over a wide range of scan rates using Butler-Volmer kinetics, whereas the Marcus-Hush model was less accurate. The reduction of 2-methyl-2-nitropropane was well simulated by both models, however Marcus-Hush required a reorganisation energy lower than expected. © 2011 Elsevier B.V. All rights reserved.
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1016/j.cplett.2011.10.004

Authors


More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Chemistry
Sub department:
Physical & Theoretical Chem
Role:
Author


Journal:
CHEMICAL PHYSICS LETTERS More from this journal
Volume:
517
Issue:
1-3
Pages:
29-35
Publication date:
2011-11-28
DOI:
ISSN:
0009-2614


Language:
English
Pubs id:
pubs:221667
UUID:
uuid:8d054d23-d897-4f6e-ac3f-ad21539a7746
Local pid:
pubs:221667
Source identifiers:
221667
Deposit date:
2012-12-19

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP