Journal article icon

Journal article

An investigation of sound levels on intensive care units with reference to the WHO guidelines

Abstract:
INTRODUCTION: Patients in intensive care units (ICUs) suffer from sleep deprivation arising from nursing interventions and ambient noise. This may exacerbate confusion and ICU-related delirium. The World Health Organization (WHO) suggests that average hospital sound levels should not exceed 35 dB with a maximum of 40 dB overnight. We monitored five ICUs to check compliance with these guidelines. METHODS: Sound levels were recorded in five adult ICUs in the UK. Two sound level monitors recorded concurrently for 24 hours at the ICU central stations and adjacent to patients. Sample values to determine levels generated by equipment and external noise were also recorded in an empty ICU side room. RESULTS: Average sound levels always exceeded 45 dBA and for 50% of the time exceeded between 52 and 59 dBA in individual ICUs. There was diurnal variation with values decreasing after evening handovers to an overnight average minimum of 51 dBA at 4 AM. Peaks above 85 dBA occurred at all sites, up to 16 times per hour overnight and more frequently during the day. WHO guidelines on sound levels could be only achieved in a side room by switching all equipment off. CONCLUSION: All ICUs had sound levels greater than WHO recommendations, but the WHO recommended levels are so low they are not achievable in an ICU. Levels adjacent to patients are higher than those recorded at central stations. Unit-wide noise reduction programmes or mechanical means of isolating patients from ambient noise, such as earplugs, should be considered.
Publication status:
Published
Peer review status:
Peer reviewed

Actions


Access Document


Publisher copy:
10.1186/cc12870

Authors


More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Clinical Neurosciences
Role:
Author
More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Clinical Neurosciences
Role:
Author


Publisher:
BioMed Central
Journal:
Critical Care More from this journal
Volume:
17
Issue:
5
Article number:
R187
Publication date:
2013-01-01
Acceptance date:
2013-09-03
DOI:
EISSN:
1466-609X
ISSN:
1364-8535


Language:
English
Keywords:
Pubs id:
pubs:421055
UUID:
uuid:7205a421-3b33-4211-b358-5b31b18af4e1
Local pid:
pubs:421055
Source identifiers:
421055
Deposit date:
2013-11-16

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP