Conference item : Poster
Thermal design, analysis, and testing of a cryogenic optical system for characterising the Ariel space telescope
- Abstract:
- This paper presents developments in the thermal design and testing of the optical ground support equipment (OGSE) used to characterise the optical performance of the Ariel space telescope at payload level. As part of ESA’s Cosmic Vision programme, Ariel will carry out transit spectroscopy on approximately 1,000 exoplanets over four years of operation. To simulate a flight-like thermal environment during payload level testing, the payload is enclosed in the cryogenic test rig which provides a 35K radiative environment. The payload is illuminated by the OGSE, which comprises an illumination module that illuminates the payload and a periscope module that steers the test beam into the payload line of sight. To enable verification of the dark current requirement in the payload’s detectors (< 1 e− pix−1 s−1), both the periscope and illumination module must be kept at 70 K. The illumination module has a two-stage thermal design consisting of a thermally isolated optical bench and a radiative shroud constructed from low-emissivity MIRO-27 sheeting. The optical bench and radiative shield are cooled using a pair of cryocoolers connected to flexible, high-conductivity copper straps. To de-risk the thermal design, a thermal breadboard of the illumination module has been constructed. Here, we present the thermal designs of the periscope and illumination module as well as the results of the thermal breadboarding activities. In particular, the cryocooler performance was found to be consistent with the manufacturer’s specifications. The thermal performance of the flexible copper straps was characterised, and the influence of thermal interface materials on interface conductance was quantified, with 40 μm graphite foil providing approximately twice the interface conductance of direct metal-to-metal contact for heaters operating at approximately 100 ◦C. The dominant thermal loads acting on the illumination module shroud were identified, and the effective emissivity of a MIRO-27-based shroud was determined to be 3.5 %. Furthermore, the periscope thermal design was experimentally verified at its operational temperature of approximately 70 K, and several critical aspects of the periscope thermal design were de-risked.
- Publication status:
- Published
- Peer review status:
- Peer reviewed
Actions
Access Document
- Files:
-
-
(Preview, Accepted manuscript, pdf, 26.9MB, Terms of use)
-
- Publisher copy:
- 10.1117/12.3104714
Authors
- Publisher:
- SPIE. Digital Library
- Host title:
- Proceedings of SPIE: Advances in Optical and Mechanical Technologies for Telescopes and Instrumentation VII
- Volume:
- 14154
- Article number:
- 250
- Publication date:
- 2026-08-21
- Acceptance date:
- 2026-03-16
- Event title:
- SPIE Astronomical Telescopes + Instrumentation 2026
- Event location:
- Copenhagen, Denmark
- Event start date:
- 2026-07-05
- Event end date:
- 2026-07-11
- DOI:
- ISSN:
-
0277-786X
- Language:
-
English
- Keywords:
- Subtype:
-
Poster
- Pubs id:
-
2454672
- Local pid:
-
pubs:2454672
- Deposit date:
-
2026-11-06
- ARK identifier:
Terms of use
- Copyright holder:
- Society of Photo-Optical Instrumentation Engineers
- Copyright date:
- 2026
- Rights statement:
- © 2026 Society of Photo-Optical Instrumentation Engineers (SPIE)
- Notes:
-
The author accepted manuscript (AAM) of this paper has been made available under the University of Oxford's Open Access Publications Policy, and a CC BY public copyright licence has been applied.
This paper was presented at SPIE Astronomical Telescopes + Instrumentation, 5-11 July 2026, Copenhagen, Denmark.
- Licence:
- CC Attribution (CC BY)
If you are the owner of this record, you can report an update to it here: Report update to this record