Journal article icon

Journal article

Minimally Invasive Subretinal Perfluorocarbon Liquid (PFCL) Removal

Abstract:
PurposePerfluorocarbon liquid (PFCL) is widely used in retinal surgery; however, it can be complicated by subretinal retention that can affect/threaten fovea. A number of different approaches have been explored to remove retained PFCL. Here, we investigate the use of microneedles with internal diameters as small as 49 G.MethodsAn in vitro model was used to examine the rate of aspiration of a fixed volume of 250 µL PFCL, whereby 30, 41, 43, and 49 gauge needles were examined. An ex vivo porcine model was then used to confirm whether subretinal PFCL could be consistently aspirated without blockage. Finally, this technique was used during pars plana vitrectomy (PPV) in 10 patients presenting with subfoveal or parafoveal retained PFCL.ResultsMean aspiration of 250 µL PFCL required 0.22, 0.33, and 0.78 minutes for the 30, 41, and 43 gauge needles at 200 mm Hg extraction pressure. Microneedle aspiration of 250 µL required maximal vacuum settings of 650 mm Hg to obtain a measurable average time to aspiration of 3.34 minutes. Ex vivo aspiration of subretinal PFCL required 400-650 mm Hg vacuum, where this was repeatable without any needle blockage. In 10 patients treated with PPV and microneedle subretinal PFCL aspiration, all cases were successful. Mean visual acuity change was of LogMAR -0.08 (±0.12).ConclusionsWe recommend the clinical use of microneedles as a minimally invasive surgical option when considering direct retained PFCL removal.Translational relevanceWe confirmed the flow properties of microneedles for PFCL aspiration in vitro and ex vivo before successfully applying this to treat retained PFCL in patients.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1167/tvst.14.12.16

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Engineering Science
Sub department:
Engineering Science
Role:
Author


Publisher:
Association for Research in Vision and Ophthalmology
Journal:
Translational Vision Science & Technology More from this journal
Volume:
14
Issue:
12
Pages:
16
Publication date:
2025-12-01
DOI:
EISSN:
2164-2591
ISSN:
2164-2591
Pmid:
41384797


Language:
English
Keywords:
Pubs id:
2360090
UUID:
uuid_63990708-a5e8-44ac-85c7-314f604a53cb
Local pid:
pubs:2360090
Source identifiers:
3581330
Deposit date:
2025-12-20
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP