Journal article icon

Journal article

Physical characteristics at the turnover-points of relative biological effect (RBE) with linear energy transfer (LET)

Abstract:
This paper considers the kinematic physical characteristics of ionic beams for maximum relative bio-effectiveness (RBE). RBE studies, based on heterogenous cell survival studies at different laboratories and linear energy transfer (LET) conditions for proton, helium, carbon, neon and argon ions, have been further analysed to determine the LETU values where RBE is maximal and the LET-RBE relationship has a turnover point. The SRIM stopping power software and other classical equations are used to determine the particle velocities, kinetic energies and their effective ionic charges at LETU. The estimated mean LETU values increase with atomic number (Z). Each LETU has a unique relativistic velocity, β  =  v/c, the velocity v expressed as a fraction of the speed of light, (c), and which is non-linearly proportional to Z. For ions helium and heavier ions, these velocities indicate that the effective charge Z * is around 0.99 of the full Z value at each LETU, with remarkably stable velocities of 3–4 nm centerdot fs−1 per nucleon, or around 6–8 nm centerdot fs−1 per unit Z. For Z  =  1, (protons and deuterium) some values fall outside these ranges but the result depends on the mix of proton and deuterium used in experiments. An alternative index of βA/Z 2 (A is the atomic mass number), suggests an average velocity of around 15 nm centerdot fs−1 for each particle at LETU. These distances, traversed in the time of the radiochemical process initiation, are all within the dimensions of the nucleosome. Curve fitting of the data set provides a predictive equation for LETU for any ion, as LETU  =  30.4  +   (1  −  Exp[−0.61  √  (Z  −  1)]) when normalised to protons. These data can be extended to heavier ions such as silicon and iron and give values that are consistent with experimental data. Each ion probably has a unique LETU value. Kinematic studies show maximum bio-effectiveness occurs at particle velocities where electron stripping remains at around 99% and where the velocity per nucleon is around 3–4 nm centerdot fs−1. This study enhances the limited prior knowledge about the physical conditions of particle beams that provide maximum bio-effectiveness, with applications in particle radiotherapy, radiation protection and space travel.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1088/1361-6560/ab52a5

Authors

More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Oncology
Sub department:
CRUK/MRC Ox Inst for Radiation Oncology
Role:
Author
More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Oncology
Sub department:
CRUK/MRC Ox Inst for Radiation Oncology
Oxford college:
Wolfson College
Role:
Author


Publisher:
IOP Publishing
Journal:
Physics in Medicine and Biology More from this journal
Volume:
64
Issue:
22
Article number:
225010
Publication date:
2019-10-30
Acceptance date:
2019-11-21
DOI:
EISSN:
1361-6560
ISSN:
0031-9155


Language:
English
Keywords:
Pubs id:
pubs:1069868
UUID:
uuid:61e3f8d7-6997-4f29-966b-b4340940f960
Local pid:
pubs:1069868
Source identifiers:
1069868
Deposit date:
2019-11-04
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP