Journal article icon

Journal article

B1+ Optimization in the Heart at 7 T

Abstract:

Purpose

At 7 T, the short RF wavelength in tissue (∼11 cm) causes destructive interference within the chest, leading to B1+ inhomogeneity and posing a critical challenge for cardiac MRI and MRS. While subject-specific parallel-transmit (pTx) optimization can mitigate this, it requires calibration scans and offline computation. To simplify this process, a static "global" shim was calculated and demonstrated to outperform the default transmit configuration without participant-specific calibration.

Methods

B1+ maps were acquired in 12 healthy volunteers at 7 T using an 8-channel 1H torso coil. "Personal" phase-only shims were calculated per subject by minimizing a cost function of B1+ homogeneity and efficiency. The "global" shim was calculated by optimizing performance across the cohort, then validated in six additional volunteers by comparing performance against the native mode.

Results

In the validation cohort, the "global" significantly outperformed the native shim. It increased the Mean Transmit Sensitivity by ∼20% and reduced CoV by ∼16% in the septum. The fixed global shim performance was within 3% of the computationally expensive personal shim for all metrics.

Conclusion

A fixed, population-derived, global phase shim provides a practical, calibration-free approach for improving cardiac B1+ performance at 7 T. The present results extend previous universal RF-shimming work through prospective evaluation in an independent validation cohort and demonstrate that much of the benefit of personal shimming can be retained without participant-specific optimization. The resulting fixed-phase configuration could also provide a practical route towards implementation on single-transmit hardware for cardiac imaging and spectroscopic applications.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.1002/mrm.70670

Authors

More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0009-0002-6653-3638
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0002-9289-5619
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0002-0780-8905
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0003-2567-3642


Publisher:
Wiley
Journal:
Magnetic Resonance in Medicine More from this journal
Publication date:
2026-11-17
Acceptance date:
2026-11-05
DOI:
EISSN:
1522-2594
ISSN:
0740-3194


Language:
English
Keywords:
Pubs id:
2499225
Local pid:
pubs:2499225
Source identifiers:
W7236103682
Deposit date:
2026-11-21
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP