MR Spectroscopy Without Water Suppression Using the Gradient Impulse Response Function

Abstract:
Purpose: Non‐water‐suppressed proton spectroscopy, 1H‐MRS, is desirable, as retaining the strong water resonance can facilitate automated online data corrections, internal concentration referencing, and monitoring of line narrowing effects in functional MRS. Removal of the water suppression module can also mitigate magnetization transfer effects and slightly reduce the minimum achievable TR and total RF power deposition. However, water suppression is typically considered essential due to eddy current‐induced antisymmetric sidebands on the water resonance that distort the spectral baseline and obscure metabolite signals. Theory and Methods: The Gradient Impulse Response Function (GIRF) was used to predict time‐dependent magnetic field perturbations during the FID that generate the artefactual sidebands. The GIRF was measured in a one‐time calibration, independent of spectroscopy acquisitions, enabling post‐processing correction of the sidebands without sequence modification or additional dedicated hardware. GIRF‐corrected non‐water‐suppressed single‐voxel‐spectroscopy (SVS) was compared to otherwise identical water‐suppressed acquisitions in eight participants at 3T using semi‐LASER and MEGA‐PRESS sequences. Results: Across participants, GIRF correction reduced sideband amplitudes to levels comparable with the spectral baseline, enabling recovery of the underlying metabolite signals. Systematic increases in quantified metabolite concentrations were observed relative to water‐suppressed acquisitions, consistent with water‐suppression‐induced magnetization transfer effects. Total creatine exhibited the largest increase, with enhancement ratios of 1.069 ± 0.039 for MEGA‐PRESS and 1.535 ± 0.160 for semi‐LASER acquisitions. Conclusion: Gradient‐induced artefactual sidebands in non‐water‐suppressed MR spectroscopy can be effectively corrected using the GIRF to predict time‐dependent magnetic field perturbations during the FID. In principle, the approach extends to other SVS sequences and field strengths following appropriate GIRF calibration.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Files:
Publisher copy:
10.1002/mrm.70383

Authors

More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0009-0007-0451-2942
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0001-7912-2251
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0001-7159-7025


More from this funder
Funder identifier:
10.13039/501100013373
Grant:
NIHR203311
More from this funder
Funder identifier:
https://ror.org/029chgv08
Grant:
203139/A/16/Z


Publisher:
Wiley
Journal:
Magnetic Resonance in Medicine More from this journal
Article number:
mrm.70383
Publication date:
2026-05-05
Acceptance date:
2026-03-31
DOI:
EISSN:
1522-2594
ISSN:
0740-3194


Language:
English
Keywords:
Pubs id:
2418829
Local pid:
pubs:2418829
Source identifiers:
4016860
Deposit date:
2026-05-06
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP