Journal article icon

Journal article

Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction

Abstract:
Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity. Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations. Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method. Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
Publication status:
Published
Peer review status:
Peer reviewed

Actions


Access Document


Files:
Publisher copy:
10.1002/mrm.30407

Authors


More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0009-0009-1006-3869
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0002-5020-5165
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0001-6272-8783
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0003-4134-374X
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0002-0329-824X


More from this funder
Funder identifier:
https://ror.org/029chgv08
More from this funder
Funder identifier:
https://ror.org/0517h6h17
More from this funder
Funder identifier:
https://ror.org/0526snb40


Publisher:
Wiley
Journal:
Magnetic Resonance in Medicine More from this journal
Publication date:
2024-12-29
Acceptance date:
2024-12-04
DOI:
EISSN:
1522-2594
ISSN:
0740-3194


Language:
English
Keywords:
Source identifiers:
2536325
Deposit date:
2024-12-30
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP