Automated localization and quality control of the aorta in cine CMR can significantly accelerate processing of the UK Biobank population data

Abstract:

Introduction Aortic distensibility can be calculated using semi-automated methods to segment the aortic lumen on cine CMR (Cardiovascular Magnetic Resonance) images. However, these methods require visual quality control and manual localization of the region of interest (ROI) of ascending (AA) and proximal descending (PDA) aorta, which limit the analysis in large-scale population-based studies. Using 5100 scans from UK Biobank, this study sought to develop and validate a fully automated method to 1) detect and locate the ROIs of AA and PDA, and 2) provide a quality control mechanism.

Methods The automated AA and PDA detection-localization algorithm followed these steps: 1) foreground segmentation; 2) detection of candidate ROIs by Circular Hough Transform (CHT); 3) spatial, histogram and shape feature extraction for candidate ROIs; 4) AA and PDA detection using Random Forest (RF); 5) quality control based on RF detection probability. To provide the ground truth, overall image quality (IQ = 0–3 from poor to good) and aortic locations were visually assessed by 13 observers. The automated algorithm was trained on 1200 scans and Dice Similarity Coefficient (DSC) was used to calculate the agreement between ground truth and automatically detected ROIs.

Results The automated algorithm was tested on 3900 scans. Detection accuracy was 99.4% for AA and 99.8% for PDA. Aorta localization showed excellent agreement with the ground truth, with DSC ≥ 0.9 in 94.8% of AA (DSC = 0.97 ± 0.04) and 99.5% of PDA cases (DSC = 0.98 ± 0.03). AA×PDA detection probabilities could discriminate scans with IQ ≥ 1 from those severely corrupted by artefacts (AUC = 90.6%). If scans with detection probability < 0.75 were excluded (350 scans), the algorithm was able to correctly detect and localize AA and PDA in all the remaining 3550 scans (100% accuracy).

Conclusion The proposed method for automated AA and PDA localization was extremely accurate and the automatically derived detection probabilities provided a robust mechanism to detect low quality scans for further human review. Applying the proposed localization and quality control techniques promises at least a ten-fold reduction in human involvement without sacrificing any accuracy.

Publication status:
Published
Peer review status:
Peer reviewed

Actions


Access Document


Publisher copy:
10.1371/journal.pone.0212272

Authors


More by this author
Institution:
University of Oxford
Division:
MSD
Department:
RDM
Sub department:
RDM Cardiovascular Medicine
Role:
Author
ORCID:
0000-0002-0452-8756
More by this author
Institution:
University of Oxford
Division:
Medical Sciences Division
Department:
RDM
Sub department:
RDM Cardiovascular Medicine
Role:
Author
More by this author
Institution:
University of Oxford
Division:
Medical Sciences Division
Department:
RDM
Sub department:
RDM Cardiovascular Medicine
Role:
Author


Publisher:
Public Library of Science
Journal:
PLoS ONE More from this journal
Volume:
14
Issue:
2
Article number:
e0212272
Publication date:
2019-02-14
Acceptance date:
2019-02-05
DOI:
ISSN:
1932-6203


Pubs id:
pubs:969433
UUID:
uuid:4ecc493c-0f7e-475d-80e8-f25398ca6e13
Local pid:
pubs:969433
Deposit date:
2019-02-08

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP