Journal article
Non-contact infrared versus axillary and tympanic thermometers in children attending primary care: a mixed-methods study of accuracy and acceptability
- Abstract:
-
Background Guidelines recommend measuring temperature in children presenting with fever using electronic axillary or tympanic thermometers. Non-contact thermometry offers advantages, yet has not been tested against recommended methods in primary care.
Aim To compare two different non-contact infrared thermometers (NCITs) to axillary and tympanic thermometers in children aged ≤5 years visiting their GP with an acute illness.
Design and setting Method comparison study with nested qualitative component.
Method Temperature measurements were taken with electronic axillary (Welch Allyn SureTemp®), electronic tympanic (Braun Thermoscan®), NCIT Thermofocus® 0800, and NCIT Firhealth Forehead. Parents rated acceptability and discomfort. Qualitative interviews explored parents’ experiences of the thermometers.
Results In total, 401 children were recruited (median age 1.6 years, 50.62% male). Mean difference between the Thermofocus NCIT and axillary thermometer was −0.14°C (95% confidence interval [CI] = −0.21 to −0.06°C); lower limit of agreement was −1.57°C (95% CI = −1.69 to −1.44°C) and upper limit 1.29°C (95% CI = 1.16 to 1.42°C). A second NCIT (Firhealth) had similar levels of agreement; however, the limits of agreement between tympanic and axillary thermometers were also wide. Parents expressed a preference for the practicality and comfort of NCITs, and were mostly negative about their child’s experience of axillary thermometers. But there was willingness to adopt whichever device was medically recommended.
Conclusion In a primary care paediatric population, temperature measurements with NCITs varied by >1°C compared with axillary and tympanic approaches. But there was also poor agreement between tympanic and axillary thermometers. Since clinical guidelines often rely on specific fever thresholds, clinicians should interpret peripheral thermometer readings with caution and in the context of a holistic assessment of the child.
- Publication status:
- Published
- Peer review status:
- Peer reviewed
Actions
Access Document
- Files:
-
-
(Preview, Accepted manuscript, 376.9KB, Terms of use)
-
- Publisher copy:
- 10.3399/bjgp20x708845
Authors
- Publisher:
- Royal College of General Practitioners
- Journal:
- British Journal of General Practice More from this journal
- Volume:
- 70
- Issue:
- 693
- Pages:
- e236-e244
- Place of publication:
- England
- Publication date:
- 2020-03-26
- Acceptance date:
- 2019-11-29
- DOI:
- EISSN:
-
1478-5242
- ISSN:
-
0960-1643
- Pmid:
-
32205332
- Language:
-
English
- Keywords:
- Pubs id:
-
1096719
- Local pid:
-
pubs:1096719
- Deposit date:
-
2020-06-08
Terms of use
- Copyright holder:
- British Journal of General Practice
- Copyright date:
- 2020
- Rights statement:
- © British Journal of General Practice 2020
- Notes:
-
This is the accepted manuscript version of the article. The final version is available online from the Royal College of General Practitioners at http://dx.doi.org/10.3399/bjgp20x708845
A correction to this article is available online at https://doi.org/10.3399/bjgp20X712769
If you are the owner of this record, you can report an update to it here: Report update to this record