Journal article
Significance of placental cord insertion site in twin pregnancy
- Abstract:
-
Objective To investigate the association between abnormal cord insertion and the development of twin‐specific complications, including birth‐weight discordance, selective fetal growth restriction (sFGR) and twin‐to‐twin transfusion syndrome (TTTS). Methods This was a single center retrospective cohort study of twin pregnancies. Abnormal cord insertion was defined as either marginal (umbilical cord attachment site less than 2 cm to the nearest margin of the ... Expand abstract
- Publication status:
- Published
- Peer review status:
- Peer reviewed
Actions
Access Document
- Files:
-
-
(Preview, Accepted manuscript, pdf, 648.4KB, Terms of use)
-
- Publisher copy:
- 10.1002/uog.18914
Authors
- Publisher:
- Wiley
- Journal:
- Ultrasound in Obstetrics and Gynecology More from this journal
- Volume:
- 52
- Issue:
- 3
- Pages:
- 378-384
- Publication date:
- 2017-10-04
- Acceptance date:
- 2017-09-12
- DOI:
- EISSN:
-
1469-0705
- ISSN:
-
0960-7692
- Pmid:
-
28976606
- Language:
-
English
- Keywords:
- Pubs id:
-
pubs:745722
- UUID:
-
uuid:288af2af-250f-4600-8475-c5f87588d9ef
- Local pid:
-
pubs:745722
- Source identifiers:
-
745722
- Deposit date:
-
2018-04-26
Terms of use
- Copyright holder:
- ISUOG
- Copyright date:
- 2017
- Notes:
- Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. This is the accepted manuscript version of the article. The final version is available online from Wiley at: https://doi.org/10.1002/uog.18914
If you are the owner of this record, you can report an update to it here: Report update to this record