Journal article icon

Journal article

Assessing the impact of different penalty factors of the Bayesian reconstruction algorithm Q.Clear on in vivo low count kinetic analysis of [11C]PHNO brain PET-MR studies

Abstract:
Introduction: Q.Clear is a Bayesian penalised likelihood (BPL) reconstruction algorithm available on General Electric (GE) Positron Emission Tomography (PET)-Computed Tomography (CT) and PET-Magnetic Resonance (MR) scanners. This algorithm is regulated by a β value which acts as a noise penalisation factor and yields improvements in signal to noise ratio (SNR) in clinical scans, and in contrast recovery and spatial resolution in phantom studies. However, its performance in human brain imaging studies remains to be evaluated in depth. This pilot study aims to investigate the impact of Q.Clear reconstruction methods using different β value versus ordered subset expectation maximization (OSEM) on brain kinetic modelling analysis of low count brain images acquired in the PET-MR. Methods: Six [11C]PHNO PET-MR brain datasets were reconstructed with Q.Clear with β100–1000 (in increments of 100) and OSEM. The binding potential relative to non-displaceable volume (BPND) were obtained for the Substantia Nigra (SN), Striatum (St), Globus Pallidus (GP), Thalamus (Th), Caudate (Cd) and Putamen (Pt), using the MIAKAT™ software. Intraclass correlation coefficients (ICC), repeatability coefficients (RC), coefficients of variation (CV) and bias from Bland–Altman plots were reported. Statistical analysis was conducted using a 2-way ANOVA model with correction for multiple comparisons. Results: When comparing a standard OSEM reconstruction of 6 iterations/16 subsets and 5 mm filter with Q.Clear with different β values under low counts, the bias and RC were lower for Q.Clear with β100 for the SN (RC = 2.17), Th (RC = 0.08) and GP (RC = 0.22) and with β200 for the St (RC = 0.14), Cd (RC = 0.18)and Pt (RC = 0.10). The p-values in the 2-way ANOVA model corroborate these findings. ICC values obtained for Th, St, GP, Pt and Cd demonstrate good reliability (0.87, 0.99, 0.96, 0.99 and 0.96, respectively). For the SN, ICC values demonstrate poor reliability (0.43). Conclusion: BPND results obtained from quantitative low count brain PET studies using [11C]PHNO and reconstructed with Q.Clear with β < 400, which is the value used for clinical [18F]FDG whole-body studies, demonstrate the lowest bias versus the typical iterative reconstruction method OSEM
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Authors

More by this author
Role:
Author
ORCID:
0000-0001-8137-5469
More by this author
Role:
Author
ORCID:
0000-0002-0471-6765
More by this author
Role:
Author
ORCID:
0000-0002-2928-1972
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0003-1102-2566
More by this author
Institution:
University of Oxford
Role:
Author
ORCID:
0000-0003-0858-6184


Publisher:
SpringerOpen
Journal:
EJNMMI Research More from this journal
Volume:
12
Issue:
1
Pages:
11-11
Article number:
11
Publication date:
2022-02-20
DOI:
EISSN:
2191-219X
ISSN:
2191-219X


Language:
English
Keywords:
Pubs id:
1274450
Local pid:
pubs:1274450
Source identifiers:
W4213267847
Deposit date:
2026-04-28
ARK identifier:
This ORA record was generated from metadata provided by an external service. It has not been edited by the ORA Team.

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP