Abstract:

We describe a mid-infrared pump – terahertz-probe setup based on a CO2 laser seeded with 10.6 μm wavelength pulses from an optical parametric amplifier, itself pumped by a Ti:Al2O3 laser. The output of the seeded CO2 laser produces high power pulses of nanosecond duration, which are synchronized to the femtosecond laser. These pulses can be tuned in pulse duration by slicing their front and back edges with semiconductor-plasma mirrors irradiated by replicas of the femtosecond seed laser pulses. Variable pulse lengths from 5 ps to 1.3 ns are achieved, and used in mid-infrared pump, terahertz-probe experiments with probe pulses generated and electro-optically sampled by the femtosecond laser.

Publication status:
Published
Peer review status:
Peer reviewed

Actions


Access Document


Publisher copy:
10.1364/oe.415140

Authors


More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Physics
Sub department:
Atomic & Laser Physics
Oxford college:
Merton College
Role:
Author
ORCID:
0000-0002-3143-0850


Publisher:
Optica
Journal:
Optics Express More from this journal
Volume:
29
Issue:
3
Pages:
3575-3583
Publication date:
2021-01-21
Acceptance date:
2020-12-27
DOI:
EISSN:
1094-4087
Pmid:
33770954


Language:
English
Keywords:
Pubs id:
1162843
Local pid:
pubs:1162843
Deposit date:
2023-04-21

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP