Conference item icon

Conference item

Performance of an irradiated LHCb prototype p-on-n silicon microstrip detector

Abstract:
A prototype silicon detector for the LHCb experiment has been irradiated non-uniformly with fluences of up to 10(15) p/cm(2) of 24 GeV protons and tested with LHC speed electronics in a test beam, After doses equivalent to one year of operation at the LHC, the detector was operational, and deteriorated after higher doses. The performance of this detector identifies particular risks associated with a p-on-n fine pitch design with a double metal layer. (C) 2002 Published by Elsevier Science B.V.
Publication status:
Published

Actions

Access Document

Publisher copy:
10.1016/S0168-9002(01)01812-5

Authors


Journal:
NUCLEAR INSTRUMENTS and METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT More from this journal
Volume:
478
Issue:
1-2
Pages:
291-295