The effect of static loading on matrix synthesis was measured in intact bovine coccygeal discs. The discs were maintained at 37 degrees C in a humid atmosphere and were perfused across their upper and lower surfaces for as long as 8 hours with media containing radioisotopes (3H-proline and 35S-sulphate) via porous filter disks embedded in Perspex (Plexiglas) holders. Static loads were applied to the disc with use of weights. The activity of free, nonincorporated isotope in the centre of the d...