Journal article icon

Journal article

Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility

Abstract:

A turbine efficiency measurement system has been developed and installed on the turbine test facility (TTF) at QinetiQ Farnborough. The TTF is an engine-scale short-duration (0.5 s run time) rotating transonic facility, which can operate as either single stage (HP vane and rotor) or 11/2 stage (HP stage with IP or LP vane). The current MT1 HP stage is highly loaded and unshrouded and is therefore relevant to current design trends. Implementation of the efficiency measurement system forms part...

Expand abstract
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1115/1.3066271

Authors


More by this author
Institution:
University of Oxford
Department:
Oxford, MPLS, Engineering Science
Role:
Author
Journal:
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME
Volume:
132
Issue:
1
Pages:
011002-011002
Publication date:
2010-01-05
DOI:
EISSN:
1528-8900
ISSN:
0889-504X
URN:
uuid:11182a31-53dc-43b3-b4b0-0317d6e0c4f0
Source identifiers:
64721
Local pid:
pubs:64721
Language:
English

Terms of use


Metrics


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP