Journal article icon

Journal article

A Novel Ventilator Design for COVID-19 and Resource-Limited Settings

Abstract:
There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability.
Publication status:
Published
Peer review status:
Peer reviewed

Actions

Access Document

Publisher copy:
10.3389/fmedt.2021.707826
Publication website:
https://doi.org/10.3389/fmedt.2021.707826

Authors


Publisher:
Frontiers Media
Journal:
Frontiers in Medical Technology More from this journal
Volume:
3
Pages:
707826-
Article number:
707826
Place of publication:
Switzerland
Publication date:
2021-10-04
Acceptance date:
2021-09-07
DOI:
EISSN:
2673-3129
ISSN:
2673-3129
Pmid:
35047946


Language:
English
Keywords:
Pubs id:
1401531
UUID:
uuid_049c0500-8b0c-4d40-8ac1-ee0616aaaaa4
Local pid:
pubs:1401531
Source identifiers:
W3204798122
Deposit date:
2026-01-29
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon