Measurement of blood pressure using the auscultatory and oscillometric methods in the same cuff deflation: validation and field trial of the AandD TM2421 monitor.

Abstract:
We have evaluated under laboratory validation conditions and in an extensive field trial the behaviour of an ambulatory monitoring device that is capable of recording both by the Korotkoff-sound and oscillometric methods in a single cuff deflation (TM2421: AandD Co, Tokyo, Japan). The effects of subject age and blood pressure (BP) level on the accuracy and field reliability of the two methods implemented in the device have been determined. In the validation phase, automatic BP measurements were compared with readings by two trained observers in 96 subjects, and the results compared with the AAMI criteria for automatic BP monitors. In the field trial phase, the performances of Korotkoff-sound and oscillometric methods over a 24-h period of ambulatory BP monitoring were compared in 515 subjects, with analysis of the agreement between the two methods in patients where both provided satisfactory recordings. In the validation phase, the Korotkoff-sound method gave satisfactory results for both systolic and diastolic BP, but the oscillometric technique narrowly failed to meet the AAMI criteria for the measurement of either systolic or diastolic BP. In the field trial, the K-sound method failed to record BP accurately in 12% of subjects whereas the oscillometric method was successful in all of these. Where both methods provided technically adequate records, agreement between mean values for each method was close. In 18% of patients, the availability of the oscillometric measurement as a 'back-up' method for the K-sound method significantly improved the number of available measurements in the monitoring period, which should result in improved accuracy and reproducibility of the ambulatory mean values.
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1038/sj.jhh.1001100

Authors


More by this author
Institution:
University of Oxford
Division:
MSD
Department:
RDM
Sub department:
RDM Cardiovascular Medicine
Role:
Author


Journal:
Journal of human hypertension More from this journal
Volume:
14
Issue:
9
Pages:
573-579
Publication date:
2000-09-01
DOI:
EISSN:
1476-5527
ISSN:
0950-9240


Language:
English
Keywords:
Pubs id:
pubs:105260
UUID:
uuid:ff253fa8-5af8-4df9-82ac-ad57145d710e
Local pid:
pubs:105260
Source identifiers:
105260
Deposit date:
2012-12-19

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP