Journal article icon

Journal article

Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma

Abstract:

Pseudotumours are well recognised as a complication of metal-on-metal hip arthroplasties and are thought to develop on the basis of an innate and adaptive immune response to cobalt-chrome (Co-Cr) wear particles. We report a case of a large pseudotumour that developed following a knee endoprosthetic replacement (EPR) undertaken for Ewing sarcoma. The lesion contained necrotic and degenerate connective tissue in which there were numerous scattered metal wear-containing macrophages, eosinophil p...

Expand abstract
Publication status:
Published
Peer review status:
Peer reviewed
Version:
Publisher's version

Actions


Access Document


Files:
Publisher copy:
10.1007/s00256-017-2610-0

Authors


More by this author
Department:
Oxford, MSD, NDORMS
Role:
Author
More by this author
Department:
Oxford, MSD, NDORMS
Role:
Author
Publisher:
Springer Berlin Heidelberg Publisher's website
Journal:
Skeletal Radiology Journal website
Volume:
46
Issue:
7
Pages:
967–974
Publication date:
2017-03-07
DOI:
EISSN:
1432-2161
ISSN:
0364-2348
Pubs id:
pubs:685194
URN:
uri:f444744f-df6f-43e3-9439-0140f7d63667
UUID:
uuid:f444744f-df6f-43e3-9439-0140f7d63667
Local pid:
pubs:685194
Paper number:
7
Language:
English
Keywords:

Terms of use


Metrics


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record