Extended electron transfer and the Frumkin correction

Abstract:

It is now well established that the rate constant for electron transfer between a metal electrode and a given redox moiety (at distance x from the electrode) decays according to exp[ - betax]; values of beta are of the order of 10(8) cm(-1) and depend primarily upon the nature of the intervening medium. The present work demonstrates how this 'extended' electron transfer can modify the Frumkin correction for diffuse layer effects in the measurement of heterogeneous rate constants. We quantify ...

Expand abstract

Actions


Authors


DJ Gavaghan More by this author
SW Feldberg More by this author
Journal:
Journal of Electroanalytical Chemistry
Volume:
491
Issue:
1
Pages:
103-110
Publication date:
2000