Journal article icon

Journal article

Alignment of the CMS muon system with cosmic-ray and beam-halo muons

Abstract:

The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme ...

Expand abstract

Actions


Access Document


Publisher copy:
10.1088/1748-0221/5/03/T03020

Authors


Journal:
Journal of Instrumentation More from this journal
Volume:
5
Issue:
3
Pages:
T03020-T03020
Publication date: