Thesis
Non-contact vital sign monitoring of pre-term infants
- Abstract:
-
Non-contact vital sign monitoring using video cameras enables the measurement of heart rate and respiratory rate to be performed without sensors attached to the skin of the patient. This provides advantages in terms of patient comfort and the management of skin irritation and infection. However, the use of non-contact technologies in the clinic presents several challenges such as variations in human skin colour, changes in lighting conditions, the detection of the presence of a patient in ...
Expand abstract
Actions
Authors
Contributors
+ Tarassenko, L
Department:
Engineering Science
Role:
Supervisor
+ Montoya, M
Department:
Engineering Science
Role:
Supervisor
Funding
+ Research Councils UK Digital Economy Programme
More from this funder
Funding agency for:
Chaichulee, S
Grant:
EP/G036861/1
Bibliographic Details
- Type of award:
- DPhil
- Level of award:
- Doctoral
- Awarding institution:
- University of Oxford
Item Description
- Language:
- English
- Keywords:
- Subjects:
- UUID:
-
uuid:cf0dabf4-30f6-45c3-bf63-70738cfb848e
- Deposit date:
- 2019-10-31
Related Items
Terms of use
- Copyright holder:
- Chaichulee, S
- Copyright date:
- 2018
Metrics