Journal article
UV-B Robertson-Berger meter characterization and field calibration
- Abstract:
-
The New Zealand Meteorological Service has used a Robertson-Berger meter (RB meter) to monitor solar UV-B radiation for the past decade. The radiometric properties of the instrument have been analyzed and agree with the standard values published by Berger. A detailed theoretical treatment of the RB meter response that fully accounts for its cosine response is presented. Field measurements made with the RB meter and with a double monochromator spectral radiometer were used to validate the theo...
Expand abstract
Actions
Authors
Bibliographic Details
- Journal:
- Applied Optics
- Volume:
- 32
- Issue:
- 3
- Pages:
- 343-349
- Publication date:
- 1993-01-20
- DOI:
- EISSN:
-
1539-4522
- ISSN:
-
1559-128X
Item Description
- Pubs id:
-
pubs:344094
- UUID:
-
uuid:b79b2d5d-9712-4bc7-9fe5-8ecbcba2a83d
- Local pid:
- pubs:344094
- Source identifiers:
-
344094
- Deposit date:
- 2012-12-19
Terms of use
- Copyright date:
- 1993
Metrics
If you are the owner of this record, you can report an update to it here: Report update to this record