Conference item
Pericardial and porcine stentless aortic valves: are they hemodynamically different?
- Abstract:
-
BACKGROUND: We sought to compare the early hemodynamic performance of pericardial stentless aortic valves with that of well-established porcine stentless aortic prostheses. METHODS: A total of 169 patients (97 men and 72 women, aged 73+/-6 years) undergoing aortic valve replacement received either a pericardial (Pericarbon, Sorin Biomedica, Saluggia, Italy; n = 89) or a porcine (Freestyle, Medtronic, n = 80) stentless aortic valve. Aortic valve hemodynamics and root dynamism were assessed by ...
Expand abstract
- Publication status:
- Published
Actions
Authors
Bibliographic Details
- Volume:
- 71
- Issue:
- 5 Suppl
- Pages:
- S311-S314
- Host title:
- The Annals of thoracic surgery
- Publication date:
- 2001-05-01
- DOI:
- EISSN:
-
1552-6259
- ISSN:
-
0003-4975
- Source identifiers:
-
350341