Journal article icon

Journal article

In vitro measurement of patellofemoral force after three types of knee replacement.

Abstract:

Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20 degrees to 120 degrees of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no significant change in the PFF. After arthroplasty with a posterior-cruciate-retaining prosthesis and divi...

Expand abstract
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1302/0301-620x.80b5.8460

Authors


More by this author
Institution:
University of Oxford
Division:
MSD
Department:
NDORMS
Role:
Author
Journal:
Journal of bone and joint surgery. British volume
Volume:
80
Issue:
5
Pages:
900-906
Publication date:
1998-09-01
DOI:
ISSN:
0301-620X
Source identifiers:
62675
Language:
English
Keywords:
Pubs id:
pubs:62675
UUID:
uuid:7985859b-0582-4db3-8571-51c38c731569
Local pid:
pubs:62675
Deposit date:
2013-11-16

Terms of use


Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP