Journal article icon

Journal article

Aligning the CMS muon chambers with the muon alignment system during an extended cosmic ray run

Abstract:
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.

Actions


Access Document


Publisher copy:
10.1088/1748-0221/5/03/T03019

Authors



Journal:
Journal of Instrumentation More from this journal
Volume:
5
Issue:
3
Pages:
T03019-T03019
Publication date:
2010-01-01
DOI:
EISSN:
1748-0221
ISSN:
1748-0221


Language:
English
Pubs id:
pubs:139045
UUID:
uuid:7393d8b9-e32e-4bbd-a5d0-20f9630aef6b
Local pid:
pubs:139045
Source identifiers:
139045
Deposit date:
2012-12-19

Terms of use



Views and Downloads






If you are the owner of this record, you can report an update to it here: Report update to this record