Journal article icon

Journal article

An investigation into the role of the optical detection set-up in the recording of cardiac optical mapping signals: A Monte Carlo simulation study

Abstract:

Photon scattering is known to distort the fluorescence signals recorded from optically mapped cardiac tissue. However, the contribution of the parameters which define the optical detection set-up has not been assessed. In this study, Monte Carlo (MC) simulations of photon scattering within ventricular tissue are combined with a detailed model of a tandem-lens optical detection apparatus to characterise (i) the spatial origin upon emission of photons recorded in voltage-sensitive fluorescence ...

Expand abstract
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1016/j.physd.2008.06.014

Authors


More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Physiology Anatomy & Genetics
Role:
Author
Journal:
PHYSICA D-NONLINEAR PHENOMENA More from this journal
Volume:
238
Issue:
11-12
Pages:
1008-1018
Publication date:
2009-06-01