Transient vertical loading of model suction caissons in a pressure chamber

Abstract:

Vertical monotonie and cyclic loading tests on model suction caissons have been carried out to explore conditions relevant to the design of multiple-footing foundations for offshore wind turbines. The tests were conducted in a pressurised chamber, which simulates up to 20m of water depth, to investigate the effect of cavitation on the ultimate tensile response of the caisson. Cyclic loading tests were also conducted at elevated pressures. Data from cyclic tests are presented to compare the re...