Stability of microbubbles prepared by co-axial electrohydrodynamic atomisation.

Abstract:

Previous studies have indicated that microbubbles prepared by co-axial electrohydrodynamic atomisation (CEHDA) are less stable than those prepared by other methods such as sonication and microfluidic techniques. The aim of this investigation was to determine the reasons for this observation and how this might be addressed in future work. Microbubbles were prepared by CEHDA using (i) a glycerol-air system, (ii) a glycerol-Tween 80-air system and (iii) a glycerol-zirconia-air system and also by...