Journal article
Theoretical analysis of the fall cone test.
- Abstract:
- In the past it has been suggested that the Liquid Limit test is essentially a strength test, and correlations have been made for the strength at the Liquid Limit. In this paper a theoretical analysis of the fall cone test is made and a direct calculation of the undrained strength at the Liquid Limit is possible. The single most important factor affecting the Liquid Limit is the cone roughness, which is not specified in the British Standard.-from US Govt Reports Announcements, 26, 1981
Actions
Authors
- Publisher:
- Oxford University, UK, Department of Engineering Science
- Publication date:
- 1981-01-01
- Language:
-
English
- Pubs id:
-
pubs:125366
- UUID:
-
uuid:3ef6dab5-0681-4af5-8d06-7e06d89ca0c1
- Local pid:
-
pubs:125366
- Source identifiers:
-
125366
- Deposit date:
-
2013-02-20
Terms of use
- Copyright date:
- 1981
If you are the owner of this record, you can report an update to it here: Report update to this record