An ink surgical marker pen is damaging to tendon cells.

Abstract:

OBJECTIVES: Surgical marking during tendon surgery is often used for technical and teaching purposes. This study investigates the effect of a gentian violet ink marker pen, a common surgical marker, on the viability of the tissue and cells of tendon. METHODS: In vitro cell and tissue methods were used to test the viability of human hamstring explants and the migrating tenocytes in the presence of the gentian violet ink. RESULTS: The outcome of this study was that a constituent of the surgica...