Journal article icon

Journal article

Evaluation of the novel Tanita body-fat analyser to measure body composition by comparison with a four-compartment model.

Abstract:

The Tanita body-fat analyser is a novel device to estimate body fat, based on the principles of bioelectrical impedance. It differs from other impedance systems which use surface electrodes in that the subjects stand bare-footed on a metal sole-plate which incorporates the electrodes, hence impedance is measured through the legs and lower trunk. In 104 men and 101 women (16-78 years and BMI 16-41 kg/m2) the mean bias in body-fat mass measured using the Tanita body-fat analyser was 0.8 (2SD 7....

Expand abstract
Publication status:
Published

Actions


Access Document


Publisher copy:
10.1017/s0007114500000155
Journal:
British journal of nutrition More from this journal
Volume:
83
Issue:
2
Pages:
115-122
Publication date:
2000-02-01
DOI:
EISSN:
1475-2662
ISSN: