Journal article
Time reconstruction and performance of the CMS electromagnetic calorimeter
- Abstract:
- The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.
Actions
Authors
Bibliographic Details
- Journal:
- Journal of Instrumentation
- Volume:
- 5
- Issue:
- 3
- Pages:
- T03011-T03011
- Publication date:
- 2010-01-01
- DOI:
- EISSN:
-
1748-0221
- ISSN:
-
1748-0221
- Source identifiers:
-
139041
Item Description
- Language:
- English
- Pubs id:
-
pubs:139041
- UUID:
-
uuid:1e2953e7-99e7-4004-a943-27b9720c005a
- Local pid:
- pubs:139041
- Deposit date:
- 2012-12-19
Terms of use
- Copyright date:
- 2010
If you are the owner of this record, you can report an update to it here: Report update to this record