Thesis
The development of non-iterative electron ptychography methods for fast and low-fluence imaging
- Abstract:
-
Electron ptychography has been a widely used imaging method in TEM due to its high resolution and adaptability to various imaging conditions, including low-fluence (low-dose) condition, focused and defocused probes. This thesis explored the development of non-iterative electron ptychography for fast imaging under low-fluence conditions, offering insights into its potential and limitations.
In this thesis, the impact of inelastic electron scattering on ptychographic reconstruction is discussed. Experiment and calculation results indicate that inelastically scattered electrons have a minimal effect on typical atomic resolution experiments. The optimized defocus condition for various accelerating voltages and convergence angles are calculated. Additionally, TDS (Thermal Diffuse Scattered) electrons do not significantly affect ptychographic reconstructions, although they may degrade resolution if dark field signals are considered. Therefore, inelastically scattered electrons can be included into the dataset for ptychography reconstruction to improve electron fluence efficiency.
Furthermore, a phase reconstruction method named as Single-Side Band masked Centre-of-mass (SSBm-COM), which combines SSB ptychography and Centre-of-mass (COM) imaging is proposed and discussed. This method applies the weak phase object approximation (WPOA) and can compensate for aberrations in 4DSTEM datasets. This method reduces the total electron fluence by minimizing the need for fine-tuning defocus before data collection.
In addition, Arbitrary Detector Ptychography (AD-ptycho), which can reconstruct data recorded on arbitrary multi-channel detectors under the weak phase object approximation (WPOA) is introduced. This method can compensate defocus and can be applied to various detector layouts, including segmented detectors which can reduce data collection time. However, the reliance on WPOA remains a theoretical constraint.
Based on AD-ptycho, Linear System Solution ptychography method (LSS) for analysing 4DSTEM datasets without relying on the WPOA is then developed. Similar to AD-ptycho, LSS can be configured to operate with non-pixelated multichannel detectors. LSS has potential for imaging non-WPOA samples with a fast segmented detector.
Actions
Access Document
- Files:
-
-
(Preview, Dissemination version, pdf, 12.1MB, Terms of use)
-
Authors
Contributors
- Institution:
- University of Oxford
- Division:
- MPLS
- Department:
- Materials
- Role:
- Supervisor
- ORCID:
- 0000-0002-5883-6463
- Institution:
- University of Oxford
- Division:
- MPLS
- Department:
- Materials
- Role:
- Supervisor
- DOI:
- Type of award:
- DPhil
- Level of award:
- Doctoral
- Awarding institution:
- University of Oxford
- Language:
-
English
- Keywords:
- Subjects:
- Pubs id:
-
2268880
- Local pid:
-
pubs:2268880
- Deposit date:
-
2025-07-17
- ARK identifier:
Terms of use
- Copyright holder:
- Zhiyuan Ding
- Copyright date:
- 2024
If you are the owner of this record, you can report an update to it here: Report update to this record