- Experimental and Computational Methods for the Evaluation of Double-Wall, Effusion Cooling Systems
- Description:
-
Further improvements in gas turbine efficiency can be sought through more advanced cooling systems – such as the double-wall, effusion system – which provide high cooling effectiveness with low coolant utilisation. The double-wall system, as described here, comprises two walls, one with a regular array of impingement holes, the other with a closely-packed, regular array of film holes (characteristic of effusion systems). These walls are mechanically and thermally connected to one another via a bank of pedestals which increase coolant wetted area and turbulent flow features. However, a lack of data exists in the open literature on these systems.This study presents a novel experimental heat transfer facility designed with the intent of investigating flat plate versions of such double-wall geometries. Key features of the facility are presented including the use of recirculation to increase mainstream-to-coolant temperature ratio and the use of infrared thermography to obtain thermal measurements. Some rig commissioning characteristics are also provided which demonstrate well-conditioned, uniform flow. Both coolant and mainstream Reynolds numbers are matched to engine conditions, with Biot number within around 15% of engine conditions.The facility is used to assess the cooling performance of four double-wall effusion geometries which incorporate various geometrical features. Both overall effectiveness and film effectiveness measurements are presented at a range of coolant mass flows with conclusions drawn as to preferable features from a cooling perspective. The results from a fully conjugate CFD model of the facility are presented which utilised boundary conditions obtained during experimental runs. Additionally, a computationally efficient decoupled conjugate method developed previously by the authors was adapted to assess the experimental geometries with the results comparing favourably.
- Related item:
- An Integrated Conjugate Computational Approach for Evaluating the Aerothermal and Thermomechanical Performance of Double-Wall Effusion Cooled Systems
- Description:
-
The drive to further increase gas turbine thermal efficiency and specific power output continue to elevate core temperatures well beyond the natural capabilities of the metals employed in their manufacture necessitating increasingly complex cooling systems.One such cooling mechanism is the double-wall, effusion-cooled system which combines in a very compact format, many cooling aspects already implemented in gas turbine cooling. To-date, thermomechanical stresses have provided one of the more significant challenges in the implementation of these systems and needs to be considered — alongside aerothermal performance — at the initial stages of design.This paper presents a novel computational method that has been developed to allow an integrated assessment of both the aerothermal and thermomechanical performance of double-wall cooling geometries. A decoupled conjugate method was developed in which internal cooling performance was ascertained via a conjugate CFD model in which the mainstream flow was not simulated. Instead, external film cooling performance was assessed via a superposition method that was developed and applied to a two-dimensionally varying correlation allowing streamwise film development to be modelled. Results of both the internal and external cooling simulations were then utilised in a conduction model to develop a complete thermal assessment of the geometry. The calculated temperature distribution was used in a thermomechanical FEA analysis permitting an insight into the stress field developed within the double-wall geometry under thermal load.The developed method was demonstrated in the assessment of seven circular pedestal, double-wall geometries in which a range of geometric parameters were investigated. The results provide an insight into the effect of varying these parameters on both the aerothermal performance of the selected geometries, along with the effect on the thermomechanical stress field developed.
- Related item:
- Development of a Steady-State Experimental Facility for the Analysis of Double-Wall Effusion Cooling Geometries
- Description:
-
The continuous drive for ever higher turbine entry temperatures is leading to considerable interest in high performance cooling systems which offer high cooling effectiveness with low coolant utilization. The double-wall system is an optimized amalgamation of more conventional cooling methods including impingement cooling, pedestals, and film cooling holes in closely packed arrays characteristic of effusion cooling. The system comprises two walls, one with impingement holes, and the other with film holes. These are mechanically connected via pedestals allowing conduction between the walls while increasing coolant-wetted area and turbulent flow. However, in the open literature, experimental data on such systems are sparse. This study presents a new experimental heat transfer facility designed for investigating double-wall systems. Key features of the facility are discussed, including the use of infrared thermography to obtain overall cooling effectiveness measurements. The facility is designed to achieve Reynolds and Biot (to within 10%) number similarity to those seen at engine conditions. The facility is used to obtain overall cooling effectiveness measurements for a circular pedestal, double-wall test piece at three coolant mass-flows. A conjugate computational fluid dynamics (CFD) model of the facility was developed providing insight into the internal flow features. Additionally, a computationally efficient, decoupled conjugate method developed by the authors for analyzing double-wall systems is run at the experimental conditions. The results of the simulations are encouraging, particularly given how computationally efficient the method is, with area-weighted, averaged overall effectiveness within a small margin of those obtained from the experimental facility.
- Related item:
- Coolant Jets Interaction in Effusion Cooling System: Experimental and Numerical Study
- Description:
-
The interaction of coolant jets is significant in effusion settings as a result of the short streamwise and spanwise distance between films. This complicates the design of effusion cooling devices because computing the interaction between numerous, closely spaced rows of films is a challenging task. A flat plate effusion cooling model is investigated at both low and high blowing ratios. Pressure sensitive paint (PSP) is used to measure film effectiveness. Computational fluid dynamics (CFD) calculations are performed to examine the cooling flow features in detail. The mesh sensitivity is studied to demonstrate the effect of mesh size on film effectiveness. The solution obtained by coarse mesh may not capture the correct trend with blowing ratio variation. Results of the computational work by fine mesh demonstrate good agreement with the measured effectiveness.Coolant jets interaction is also investigated. The profile of quantities such as velocity, temperature, kinetic energy and Reynolds stress at several locations in the flow field is compared. The boundary layer profiles are scaled by the thermal boundary layer thickness to study the feature of heat transfer. It is observed that profiles of the flow quantities are self-similar. Two distinct scalings are found: an outer scaling based on boundary layer thickness which collapses the upper part of the profiles; an inner scaling which collapses the profiles at distances from the wall comparable to the penetration depth of a single jet. The latter scaling is based on the distance from the wall to the minimum temperature profile. This distance identifies the location of the coolant leaving the effusion cooling device.
- Related item:
- High Resolution Experimental and Computational Methods for Modelling Multiple Row Effusion Cooling Performance
- Description:
-
The continuing rise in turbine entry temperatures has necessitated the development of ever-more advanced cooling techniques. Effusion cooling is an example of such a system and is characterised by a high density of film cooling holes that operate at low blowing ratios, thereby achieving high overall cooling effectiveness. This paper presents both an experimental and computational investigation into the cooling performance of effusion systems. Two flat-plate geometries (with primary hole pitches of 3.0D and 5.75D) are experimentally investigated via a pressure sensitive paint technique yielding high resolution film effectiveness distributions via heat-mass transfer analogy. A computational fluid dynamics (CFD) scalar tracking method was used to model the setup computationally with the results comparing favourably to those obtained from the experiments. The CFD domain was modified to assess the cooling performance from a single film hole ejection. A superposition method was developed and applied to the resulting two-dimensional film effectiveness distribution that quickly yielded data for an array of closely-packed holes, allowing a rapid assessment of a multi-hole effusion type setup. The method produced satisfactory results at higher pitches, but at lower pitches, high levels of jet interactions reduced the performance of the superposition method.
- Related item:
- A Three-Dimensional Conjugate Approach for Analyzing a Double-Walled Effusion-Cooled Turbine Blade
- Description:
-
A double-wall cooling scheme combined with effusion cooling offers a practical approximation to transpiration cooling which in turn presents the potential for very high cooling effectiveness. The use of the conventional conjugate computational fluid dynamics (CFD) for the double-wall blade can be computationally expensive and this approach is therefore less than ideal in cases where only the preliminary results are required. This paper presents a computationally efficient numerical approach for analyzing a double-wall effusion cooled gas turbine blade. An existing correlation from the literature was modified and used to represent the two-dimensional distribution of film cooling effectiveness. The internal heat transfer coefficient was calculated from a validated conjugate analysis of a wall element representing an element of the aerofoil wall and the conduction through the blade solved using a finite element code in ANSYS. The numerical procedure developed has permitted a rapid evaluation of the critical parameters including film cooling effectiveness, blade temperature distribution (and hence metal effectiveness), as well as coolant mass flow consumption. Good agreement was found between the results from this study and that from literature. This paper shows that a straightforward numerical approach that combines an existing correlation for film cooling from the literature with a conjugate analysis of a small wall element can be used to quickly predict the blade temperature distribution and other crucial blade performance parameters.