All things hydrogen: hydrogen imaging in atom probe tomography and its application to tungsten

Abstract:

This thesis investigates the fundamental behaviour of contaminant hydrogen in Atom Probe Tomography (APT), develops an APT imaging method for sample hydrogen, applies it to deuterium implanted tungsten, and describes a large-scale APT data analysis and its application to hydrogen.

Rate cycling experiments are introduced, where the evaporation rate or frequency is repeatedly changed during experiments. Contaminant hydrogen is, other than sample hydrogen, rate dependent, therefore this allows estimating the true amount of sample hydrogen. By undertaking APT experiments below the evaporation threshold, it could then be investigated how the electric field influences the contaminant signal on tungsten. Beyond a critical field strength, the contaminants are found to evaporate with a detectable energy deficit. This allows differentiation between contaminant and sample hydrogen, which evaporates without any energy deficit, enabling development of a method for direct hydrogen imaging using pulsed laser APT.

The technique is applied to image deuterium in self-ion irradiated, deuterium implanted tungsten. The deuterium is retained with a characteristic depth distribution, which is imaged by APT with high spatial resolution. The highest deuterium concentrations are found in a layer directly under the material surface (up to 20 nm deep), corresponding to the depth reached by the deuterium during implantation, and in a deeper layer (ca 120 to 170 nm below) due to radiation damage. The scatter of measured concentrations across samples is large, and potentially requires further study.

Finally, a large-scale data analysis, covering 848 archival datasets from the Oxford APT group is presented. It is shown that many APT spectra can be regarded as a point cloud, in which a similarity metric based on the city block distance is well suited to search spectra by similarity. The point cloud contains clusters, mostly due to chemical composition of the underlying APT specimens. The dependence of contaminant hydrogen behaviour on material, voltage and electric field strength is studied.

Actions

Access Document

Files:

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Materials
Role:
Author

Contributors

Role:
Contributor
Role:
Supervisor
Role:
Supervisor
Role:
Supervisor
Role:
Examiner


DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
University of Oxford


Language:
English
Subjects:
Deposit date:
2024-03-26
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP